Daugiafunkcinis skaitmeninis testeris | TRUE RMS LCD 4000 (YT-730894) (Kodas: YT-730894)
Naujiena








Prekių nuotraukos skirtos tik iliustraciniams tikslams, originalių produktų spalvos, užrašai, parametrai, matmenys, dydžiai, funkcijos, ir/ar bet kurios kitos savybės dėl savo vizualinių ypatybių gali atrodyti kitaip negu realybėje, todėl prašome vadovautis prekių savybėmis, kurios nurodytos prekių aprašymuose. Kilus klausimams, visada laukiame Jūsų skambučio telefonu +370 650 61061 arba el. paštu info@drdtools.lt.
Gamintojas: Yato
YT-730894
TRUE RMS LCD 4000 DIGITAL METER
Brand
Yato
Entity responsible for this product in the EU
TOYA S.A.More
Measurement of alternating voltage
0-600 V a.c. Measurement of direct voltage
0-600 V d.c.
AC Current
0-10 A
DC Current
0-10 A
Resistance Measurement
0-40 MΩ
Frequency Measurement
0-3 MHz
Continuity Test
0-50 MΩ
Diode Test
yes
TRUE RMS
yes
Data Hold
yes
Non-contact AC Voltage Detection NCV
yes
Dimensions
120x60x30 mm
Material
ABS
Display Type
LCD
LED Backlight
yes
Display Range
4000
Sound Signal
yes
Automatic Measuring Range
yes
Sampling Rate
3 times per second
Automatic Power Off
15 min
Low Battery Indicator
yes
Power Supply
Battery
Battery Type
2x1.5V; AA
Operating temperature range
0~40 ˚C
Relative working humidity Rh
<75 %
Storage temperature
-10 ~ +50 ˚C
Weight
0.115 kg
Application
electrical
Symbol
YT-730894 Universal meter with TRUE RMS function and automatic range for each measurement. Allows to perform basic and advanced measurements of electrical quantities. The meter has a large backlit LCD display and a fast and precise measurement system. The solid housing is equipped with a red PVC holster, which reduces the risk of damage during a fall and - thanks to its anti-slip structure - slipping out of hands. Basic measurements: AC voltage: 0-600 V, TRUE RMS (40-1000 Hz)
DC voltage: D.C. 0-600 V
AC Current: A.C. 0-10 A, TRUE RMS (40-1000 Hz)
DC Current: D.C. 0-10 A
Resistance: 0-40 MΩ
Diode Test: IF 0.3 mA, UR 2.3 V
Continuity Test: 0-50 Ω
Additional Measurements: Frequencies: 0-3 Mhz
Non-Contact AC Voltage Detection: NCV
Accuracy: Example of determining accuracy for AC voltage measurement. Calculations for the 235 V measurement result: the YT-730894 meter's measurement accuracy for this range is: ±(1% + 3), resolution 0.1 V
measurement error calculation formula: (measurement result x 1%) + 3 x resolution
calculations: (235 x 1%) + 3 x 0.1 = 2.35 + 0.3 = 2.65 V
Actual result taking into account the measurement error for the 235 V indication = 235 ± 2.65 V result taking into account the measurement error for the DC voltage measurement indication: 12 V = 12 ± 0.09 V
result taking into account the measurement error for the AC current measurement indication: 8 A = 8 ± 0.15 A
The table with the resolution and accuracy for a given measurement can be found in the user manual. Functions: TRUE RMS - the meter displays the true effective value of the alternating voltage/current. Unlike averaging meters, devices with TRUE RMS display the correct value not only for a sinusoidal waveform, but also for distorted sinusoidal waveforms, e.g. higher harmonics or square or triangular waveforms. A mandatory function wherever there are switching power supplies, motor inverter drives, HVAC installations, etc. in the circuit.
NCV - non-contact detection of alternating voltage by inductive method. The meter detects the presence of voltage in an insulated wire using the NCV sensor on the front of the device
AUTO - automatic adjustment of the measurement range (one measurement is enough), activated by default. In the case of measuring unknown values using a meter with manual range change using the knob, measurements should be performed successively from the largest range to the range giving the most accurate result - otherwise we risk damaging the device.
SEL - change of measurement mode, e.g. from AC to DC voltage measurement
HOLD - saves the currently measured value on the display
Additional information: LCD display, maximum displayed result: 3999
backlighting
sound signal in the continuity test for resistance below 50 Ω
automatic switching of the diode test to the continuity test for circuit resistance below 50 Ω (it is not possible to set the meter only to the diode test)
12 cm long measuring probes
length of the cable with probes: 80 cm
diameter of the cable with insulation: 3 mm
wire insulation: PVC
construction with overload protection
housing made of ABS plastic
automatic shutdown of the meter after 15 minutes of inactivity (this function can be disabled)
built-in LED on the back of the housing to illuminate, e.g. the measurement location
low battery indicator
power supply: 2 x 1.5 V (AA) batteries

TRUE RMS LCD 4000 DIGITAL METER
Brand
Yato
Entity responsible for this product in the EU
TOYA S.A.More
Measurement of alternating voltage
0-600 V a.c. Measurement of direct voltage
0-600 V d.c.
AC Current
0-10 A
DC Current
0-10 A
Resistance Measurement
0-40 MΩ
Frequency Measurement
0-3 MHz
Continuity Test
0-50 MΩ
Diode Test
yes
TRUE RMS
yes
Data Hold
yes
Non-contact AC Voltage Detection NCV
yes
Dimensions
120x60x30 mm
Material
ABS
Display Type
LCD
LED Backlight
yes
Display Range
4000
Sound Signal
yes
Automatic Measuring Range
yes
Sampling Rate
3 times per second
Automatic Power Off
15 min
Low Battery Indicator
yes
Power Supply
Battery
Battery Type
2x1.5V; AA
Operating temperature range
0~40 ˚C
Relative working humidity Rh
<75 %
Storage temperature
-10 ~ +50 ˚C
Weight
0.115 kg
Application
electrical
Symbol
YT-730894 Universal meter with TRUE RMS function and automatic range for each measurement. Allows to perform basic and advanced measurements of electrical quantities. The meter has a large backlit LCD display and a fast and precise measurement system. The solid housing is equipped with a red PVC holster, which reduces the risk of damage during a fall and - thanks to its anti-slip structure - slipping out of hands. Basic measurements: AC voltage: 0-600 V, TRUE RMS (40-1000 Hz)
DC voltage: D.C. 0-600 V
AC Current: A.C. 0-10 A, TRUE RMS (40-1000 Hz)
DC Current: D.C. 0-10 A
Resistance: 0-40 MΩ
Diode Test: IF 0.3 mA, UR 2.3 V
Continuity Test: 0-50 Ω
Additional Measurements: Frequencies: 0-3 Mhz
Non-Contact AC Voltage Detection: NCV
Accuracy: Example of determining accuracy for AC voltage measurement. Calculations for the 235 V measurement result: the YT-730894 meter's measurement accuracy for this range is: ±(1% + 3), resolution 0.1 V
measurement error calculation formula: (measurement result x 1%) + 3 x resolution
calculations: (235 x 1%) + 3 x 0.1 = 2.35 + 0.3 = 2.65 V
Actual result taking into account the measurement error for the 235 V indication = 235 ± 2.65 V result taking into account the measurement error for the DC voltage measurement indication: 12 V = 12 ± 0.09 V
result taking into account the measurement error for the AC current measurement indication: 8 A = 8 ± 0.15 A
The table with the resolution and accuracy for a given measurement can be found in the user manual. Functions: TRUE RMS - the meter displays the true effective value of the alternating voltage/current. Unlike averaging meters, devices with TRUE RMS display the correct value not only for a sinusoidal waveform, but also for distorted sinusoidal waveforms, e.g. higher harmonics or square or triangular waveforms. A mandatory function wherever there are switching power supplies, motor inverter drives, HVAC installations, etc. in the circuit.
NCV - non-contact detection of alternating voltage by inductive method. The meter detects the presence of voltage in an insulated wire using the NCV sensor on the front of the device
AUTO - automatic adjustment of the measurement range (one measurement is enough), activated by default. In the case of measuring unknown values using a meter with manual range change using the knob, measurements should be performed successively from the largest range to the range giving the most accurate result - otherwise we risk damaging the device.
SEL - change of measurement mode, e.g. from AC to DC voltage measurement
HOLD - saves the currently measured value on the display
Additional information: LCD display, maximum displayed result: 3999
backlighting
sound signal in the continuity test for resistance below 50 Ω
automatic switching of the diode test to the continuity test for circuit resistance below 50 Ω (it is not possible to set the meter only to the diode test)
12 cm long measuring probes
length of the cable with probes: 80 cm
diameter of the cable with insulation: 3 mm
wire insulation: PVC
construction with overload protection
housing made of ABS plastic
automatic shutdown of the meter after 15 minutes of inactivity (this function can be disabled)
built-in LED on the back of the housing to illuminate, e.g. the measurement location
low battery indicator
power supply: 2 x 1.5 V (AA) batteries